A safety barrier reduces the probability or the severity of a scenario. Its performance is measured by its probability of failure on demand (PFD) or by its confidence level (CL).

Link between barrier, PFD and scenario probabilityInitiating event: probability Pe; Barrier with confidence level CL; PFD = 10⁻ᶜᴸ; Scenario: Ps = Pe × PFDInitiating event: probability PeBarrier with confidence level CLPFD = 10⁻ᶜᴸScenario: Ps = Pe × PFD
Each confidence level divides the scenario probability by 10.

Four possible roles

Elimination

A design change makes the scenario disappear (substitution of a product, inventory reduction).

Prevention

The barrier reduces the probability of occurrence of the initiating event.

Control

The barrier limits deviations so as not to lose control of the process.

Protection

The barrier limits the extent of damage by protecting the target from hazardous phenomena.

On the timeline of an accident: normal conditions, then deviation, loss of control, hazardous phenomenon, impact on targets and damage. Elimination and prevention act upstream of the deviation, control before the loss of control, protection after the hazardous phenomenon.

Implementation of a barrier

Classification

FamilySub-familyExamples
Barriers passives (static material barriers)Walls, bunds, slabsContainment bund, earth berm, fire wall
Immaterial, symbolic barriersInstructions, marking, signage
Mixed barriers
Barriers activesSafety instrumented systems (SIS)Sensor, safety PLC, shut-off valve
Active material barriers, non-instrumentedRelief valve, rupture disc, check valve
Manually operated systems, human barriersEmergency stop, operator intervention on alarm

The term “barrier” comes from the source-flow-target model: a barrier prevents the flow generated by the source from reaching its target or reduces it. On the bow-tie, prevention barriers are placed to the left of the top event (TE) and protection barriers to its right.

Equivalence with the fault tree

A barrier in a bow-tie is equivalent, in a fault tree, to an AND gate between the initiating event (or the effect) and the failure of the barrier: the scenario takes place only if the initiating event occurs et and the barrier fails.

Formula

Ps = Pe × PFD = Pe × 10−CL

Link between PFD, confidence level and risk reduction

CLAverage PFDRisk reduction (RR)
410-5 ≤ PFDavg < 10-410,000 < RR ≤ 100,000
310-4 ≤ PFDavg < 10-31,000 < RR ≤ 10,000
210-3 ≤ PFDavg < 10-2100 < RR ≤ 1,000
110-2 ≤ PFDavg < 10-110 < RR ≤ 100
010-1 ≤ PFDavg < 11 < RR ≤ 10

Worked examples

Assessing the relevance of a barrier

Conditions

This reasoning requires barriers that are independent of one another and of the initiating event (no common cause), and an average PFD that is valid over the period considered (periodic tests). A barrier that depends on the same power supply or the same operator as the cause cannot be credited as independent.

Key takeaway

PFD = 10−CL. Each confidence level divides the probability of the scenario by 10. A barrier counts in the calculation provided it is independent, effective and tested.

To decide quelles barriers to add and with what confidence level, the LOPA method (lesson 1-2) generalises this calculation to all the protection layers of a scenario.